BEKO American fridge freezer fault codes
To book an experienced BEKO fridge – freezer engineer call 0203 8927620 or 07706 937561
E0 - Freezer thermistor failure
Compressor and freezer fan run continuously. Freezer bar-graph display will be off.
- Displayed if measured sensor value is open circuit or short circuit
- Resets if the sensor value is correct (not open or short) error is omitted
- Check wiring
- Replace sensor
- Check control module
E1 - Fridge DEFROST SENSOR FAILURE
Defrost heater will be switched on for 25 minutes during normal defrost.
- Check wiring
- Replace sensor
- Check control module
E3 - Fridge thermistor or sensor failure
Fridge bar-graph display will be off. Sensor value is incorrect either open or short.
- Check wiring
- Replace sensor
- Replace control module
E4 - Defrost heater failure
- Check wiring
- Check defrost heater for continuity
- Check module
E8 - Icemaker or ice thermistor sensor failure
- CHECK ICE MAKER WIRING
- CHECK ICE MAKER SENSOR
- CHECK MAIN MODULE
E9 – ICE MACHINE FAULT
- CHECK WIRING
- CHECK ICE MAKER UNIT